Thies First Class POT Wind Vane
High-precision electronic POT wind direction sensor with classic potentiometer-compatible wiring and wear-free electronic sensing, available in standard and heated configurations.
Typical Applications
- Wind resource assessment
- Wind-farm monitoring
- Wind turbine site assessment
- Meteorological stations
- Existing potentiometric measurement systems
- Met-mast installations
- Wind direction monitoring
- Environmental stations
- Wind-energy research
- Cold-climate installations with S21230H
Product Enquiry
Thies First Class POT Wind Vane
High-precision electronic POT wind direction sensor with classic potentiometer-compatible wiring and wear-free electronic sensing, available in standard and heated configurations.
Typical Applications
- Wind resource assessment
- Wind-farm monitoring
- Wind turbine site assessment
- Meteorological stations
- Existing potentiometric measurement systems
- Met-mast installations
- Wind direction monitoring
- Environmental stations
- Wind-energy research
- Cold-climate installations with S21230H
The Thies First Class POT Wind Vane is a robust, high-precision analogue wind direction transmitter for wind-resource assessment, meteorological stations and wind-energy monitoring. Instead of relying on a mechanically stressed conventional potentiometer, its electronics emulate potentiometer behaviour while avoiding mechanical wear and ageing, while retaining wiring compatibility with classic potentiometric wind vanes and Ammonit data-acquisition systems. The First Class platform provides full 0–360° wind direction measurement, low starting threshold, short dynamic response and rugged outdoor construction, while the S21230H configuration adds electronically regulated heating for cold and icing-prone installations.
Key Features
- Active electronic POT measurement
- 0–360° wind direction range
- Approximately ±1° precision for the active First Class POT architecture
- 0.35° resolution
- Analogue output
- Potentiometer-compatible wiring
- No mechanical potentiometer wear
- Low starting threshold
- Short 1.8 m distance constant
- Damping ratio greater than 0.3
- Aluminium construction
- IP55 environmental protection
- -50°C to +80°C operating range
- Optional electronically regulated heating
- 24 V AC/DC heating system
The POT version is useful when an existing station is already wired for traditional potentiometric wind vanes. Its electronic architecture maintains compatible analogue behaviour while removing the mechanical contact wear normally associated with a physical potentiometer.
Product Models

S21230
- Thies First Class POT Wind Vane S21230
- Electronic potentiometer-compatible wind direction sensor
- Measurement range 0 to 360 degrees
- High-precision First Class directional measurement architecture
- Approximately ±1° wind direction accuracy
- Angular resolution approximately 0.35°
- Low starting threshold for responsive direction measurement
- Distance constant approximately 1.8 m
- Damping ratio greater than 0.3
- Electronic design avoids mechanical potentiometer wear
- Analogue signal compatible with potentiometric measurement systems
- Designed for non-heated installations
- Robust anodised aluminium outdoor construction
- Ambient operating temperature approximately -50°C to +80°C
- Suitable for wind resource meteorology and wind-energy monitoring

S21230H
- Thies First Class POT Wind Vane S21230H
- Heated electronic potentiometer-compatible wind direction sensor
- Measurement range 0 to 360 degrees
- High-precision First Class directional measurement architecture
- Approximately ±1° wind direction accuracy
- Angular resolution approximately 0.35°
- Low starting threshold for responsive direction measurement
- Distance constant approximately 1.8 m
- Electronic design avoids mechanical potentiometer wear
- Analogue signal compatible with classic potentiometric wiring
- Electronically regulated heating protects the bearing region
- Heating controlled automatically using temperature sensing
- 24 V AC/DC heating system with approximately 25 W power
- Ambient operating temperature approximately -50°C to +80°C
- Designed for demanding cold-climate wind monitoring installations
The Thies First Class POT Wind Vane is a robust, high-precision analogue wind direction transmitter for wind-resource assessment, meteorological stations and wind-energy monitoring. Instead of relying on a mechanically stressed conventional potentiometer, its electronics emulate potentiometer behaviour while avoiding mechanical wear and ageing, while retaining wiring compatibility with classic potentiometric wind vanes and Ammonit data-acquisition systems. The First Class platform provides full 0–360° wind direction measurement, low starting threshold, short dynamic response and rugged outdoor construction, while the S21230H configuration adds electronically regulated heating for cold and icing-prone installations.
Key Features
- Active electronic POT measurement
- 0–360° wind direction range
- Approximately ±1° precision for the active First Class POT architecture
- 0.35° resolution
- Analogue output
- Potentiometer-compatible wiring
- No mechanical potentiometer wear
- Low starting threshold
- Short 1.8 m distance constant
- Damping ratio greater than 0.3
- Aluminium construction
- IP55 environmental protection
- -50°C to +80°C operating range
- Optional electronically regulated heating
- 24 V AC/DC heating system
The POT version is useful when an existing station is already wired for traditional potentiometric wind vanes. Its electronic architecture maintains compatible analogue behaviour while removing the mechanical contact wear normally associated with a physical potentiometer.
Additional information
| Models | S21230, S21230H |
|---|